AmpNexus

Rolec hardware evidence profile

7 kW Twin

Verified for Sentinel's OCPP operational-evidence baseline, with model-specific enhanced telemetry kept separate until an additional mapping is approved.

Model evidence at a glance

Verified for Sentinel's OCPP operational-evidence baseline, with model-specific enhanced telemetry kept separate until an additional mapping is approved.

This profile verifies the stated Sentinel integration scope. It is not electrical safety certification, regulatory approval, a warranty or a claim that every optional signal is available on every unit.

AmpNexus verified: AmpNexus has verified the published integration and capability scope shown on this profile.

Hardware evidence scorecard

Rolec 7 kW Twin

Certification, integration and observable signals are assessed separately.

  • OCPP certificationNot evidenced
  • AmpNexus integrationVerified
  • Operational stateVerified
  • ConnectivityVerified
  • Charging sessionsVerified
  • EnergyVerified
  • VoltageNot evidenced
  • CurrentNot evidenced
  • PowerNot evidenced
  • TemperatureNot evidenced
  • RCD diagnosticsNot evidenced
  • Contactor feedbackNot evidenced
  • Fault / reset evidencePartial
  • Vendor APINot evidenced
Sentinel assurance
Observed
Observability coverage
5 / 12

Coverage counts signal areas with published verified or partial evidence. It is not a charger health score.

Evidence flow

From charger to Sentinel

Illustrative model scope

Charger

Rolec

7 kW Twin

ACAmpNexus verified
Device evidence
OCPP operational baseline
Sentinel

Published evidence lanes

Identity
State
Meter
Events
  • Meaning
  • Timestamps
  • Provenance
  • Limitations
Sentinel retains the source story and publishes only the capability supported by the applicable model, firmware, configuration and integration evidence.

Scope

Model
7 kW Twin
Variant or configuration
AmpNexus OCPP connection with status, transaction and meter-value reporting enabled
Firmware
Connected portfolio firmware identified during onboarding and boot evidence
Geography or network context
UK connected estates
Evidence last reviewed
2026-08-09
Mapping and integration scope
1 integration record

Integration paths

OCPP

OCPP operational baseline

Published

Connected units using the AmpNexus OCPP path with the required messages enabled.

Mapping version
sentinel-ocpp-baseline-v1
Last verified
2026-08-09

Integration limitations

  • Optional and vendor-specific telemetry depends on firmware, configuration and documented mappings.
  • A protocol connection does not by itself establish access to thermal, contactor, CP/PP or RCD evidence.

Capability evidence

  • Availability and state

    Connector operational state

    Verified
    Integration source
    rolec-7kw-twin-ocpp-baseline
    Availability conditions
    Available while the charge point is connected and sending OCPP status events.
    Units or meaning
    Available, Preparing, Charging, Suspended, Finishing, Unavailable and Faulted states are retained with timestamps.
    Freshness or cadence
    Event driven
    Evidence source
    AmpNexus OCPP core and Sentinel device-health implementation
    Last verified
    2026-08-09

    Sentinel keeps the source state and timestamp attached to the normalised operational view.

  • Connectivity

    Connection and heartbeat evidence

    Verified
    Integration source
    rolec-7kw-twin-ocpp-baseline
    Availability conditions
    Available for active AmpNexus OCPP connections.
    Units or meaning
    Connect, disconnect and heartbeat timing with the applicable charge-point identity.
    Freshness or cadence
    Connection event and configured heartbeat cadence
    Evidence source
    AmpNexus OCPP core and Sentinel device-health implementation
    Last verified
    2026-08-09
  • Sessions and metering

    Charging sessions and energy

    Verified
    Integration source
    rolec-7kw-twin-ocpp-baseline
    Availability conditions
    Available when transaction and meter-value messages are enabled by the charger configuration.
    Units or meaning
    Session state, timestamps and reported energy retain their source units and mapping context.
    Freshness or cadence
    Transaction events and configured meter-value cadence
    Evidence source
    AmpNexus OCPP core and Sentinel device-health implementation
    Last verified
    2026-08-09
  • Faults and incidents

    Reported fault and incident evidence

    Verified
    Integration source
    rolec-7kw-twin-ocpp-baseline
    Availability conditions
    Available when the charger reports a faulted connector state or supported device-health event.
    Units or meaning
    Source status, error context, classification and evidence confidence.
    Freshness or cadence
    Event driven
    Evidence source
    AmpNexus OCPP core and Sentinel device-health implementation
    Last verified
    2026-08-09
  • Device identity

    Firmware identity

    Partially verified
    Integration source
    rolec-7kw-twin-ocpp-baseline
    Availability conditions
    Available when firmware identity is supplied through boot or inventory evidence.
    Units or meaning
    Manufacturer-reported firmware version string.
    Freshness or cadence
    At boot and during applicable inventory refreshes
    Evidence source
    AmpNexus OCPP core and Sentinel device-health implementation
    Last verified
    2026-08-09

    A firmware string establishes identity context; it does not prove that every optional capability is enabled.

Evidence boundary

What is not yet evidenced

  • No model-specific temperature source is included in the published OCPP baseline profile.
  • Contactor command/output, CP/PP and RCD evidence require an approved manufacturer mapping or vendor API where the standard integration does not expose them.
  • Optional device-specific fault fields remain scoped to the firmware and configuration that emits them.

How to improve this profile

Expose and verify more evidence

  • Provide a manufacturer-maintained firmware and capability matrix.
  • Document approved vendor API or OCPP DataTransfer fields for model-specific telemetry.
  • Verify thermal, protection, contactor and control-pilot evidence for a higher Sentinel evidence level.
Review the firmware evidence readiness guide

Evidence sources and review

  • AmpNexus portfolio hardware inventory
  • AmpNexus OCPP core and Sentinel device-health implementation

Assess Rolec 7 kW Twin in your estate

Confirm the installed firmware, configuration and connection route so the published profile can be applied to your assets without losing the evidence boundary.